SSM 6000 Phyto
Phyto monitoring
Measurements of ethylene and carbon dioxide in plants and crops
The SSM 6000 Phyto stationary analysis system is used for continual measurements of ethylene and carbon dioxide in plants and crops.
Using gas exchange measurements on plant parts (such as on leaves or fruits), it is possible to determine information on plant growth and biological activity. Conditions for plant growth can be optimized and resource usage can be minimized by measuring the concentrations of ethylene and carbon dioxide.
The limit values for plant stress conditions can be determined using these measured variables. This information can then be used in conjunction with an automation system to provide process control within the greenhouse.
Example of usage:
Fully automatic continuous monitoring of plant physiological data in tomato greenhouses: for improving the yield or discovering energy saving potential. Integration of the data obtained into the greenhouse control mechanism.
Measured data collected:
– CO2 gas changes (photosynthesis, respiration)
– Leaf temperature
– Photosynthetically active radiation (PAR)
– Global radiation
– Leaf transpiration
Art.-Nr. | Article incl. VAT, excl. Shipping costs | Cart | |
---|---|---|---|
30006000 | SSM 6000 Phyto | Request Price | |
Show Cart |
Measurement range: | |
C2H4 | 10 ppm |
CO2 | 2,000 ppm |
Measurement technique: | |
C2H4 | electro-chemical sensor |
CO2 | NDIR measurement |
Resolution: | |
C2H4 | 1 ppb |
CO2 | 0.1 ppm |
Repeat accuracy: | |
C2H4 | 2% of measured value |
CO2 | 2% of measured value |
Detection limit (2o ~): | |
C2H4 | 2 ppb |
CO2 | 2 ppm |
Long-term stability: | |
C2H4 | excellent long-term stability |
CO2 | excellent long-term stability with proCAL |
Display: | 4-character LED display, status screens, 4-character LCD display |
Communication port: | RS232, 4 to 20 mA |
Operating temperature: | + 5 to +40 °C |
Power supply: | AC 85-264 VAC, 47-63 Hz |
Protection degree: | IP40 |
Dimensions and weight:: | 450 x 135 x 300 mm, approx. 10 kg |
Options: | Profibus DP, several measuring points, etc. |
Special features: | Data storage |